Spark GO Firmware Troubleshooting¶
Firmware update error¶
Stuck at 2% / Error Code: -2¶
-
Ask the user to try again. Make sure to connect Spark GO to the computer and launch the updater, THEN power on Spark GO.
-
If issue persists, please offer log tool with Zendesk macro Spark GO::Firmware Update Log and see if it works.
Error Code: 13/14¶
-
After entering update mode, the computer doesn't recognize the device or fails to communicate with it. Try unplugging and reconnecting the USB, then run the update again.
-
The error code indicates Python installation can not be completed. Please ask the user to try and again with the correct updating process, as instructed on the Help Center.
-
If issue persists, please offer log tool with Zendesk macro Spark GO::Firmware Update Log and see if it works.
Error code: 15¶
- The path contains non-English characters. Move the updater or log tool to a path with only English characters, such as C:.
Error code: 16¶
- The update failed midway. Try switching the USB port and run the update again.
Firmware Update Fail¶
-
Ask the user to try again. If issue persists, please offer log tool with Zendesk macro Spark GO::Firmware Update Log and see if it works.
-
Please highlight the log to Dans for further investigation.
Firmware update broke Spark GO¶
Firmware updated, amp power on but no sound¶
-
Try factory reset
-
If issue persists, please offer log tool with Zendesk macro Spark GO::Firmware Update Log and see if it works.
-
If issue persists, please highlight to Dans and WeiTing, and collect the machine back to Taipei office for further investigation.
Firmware updated, Bluetooth no longer connects¶
- First, verify if the connection issue has to do with the known issue where devices running refresh rate higher than 60hz will cause Spark app to disconnect.
-
If the issue only occurs after firmware update, ask the user to forget previous Bluetooth connection on their phone, and try connecting again.
-
If issue persists, please offer log tool with Zendesk macro Spark GO::Firmware Update Log and see if it works.
-
Please highlight the log to Dans for further investigation.
Firmware bricked the amp, cannot power on¶
-
If the amp is totally bricked and cannot power on anymore, please proceed with DOA/RMA.
-
Highlight to Dans and WeiTing, and collect the machine back to Taipei office for further investigation.